Areias engineering provides the service of helping our customers design and build manufacturing, laboratory equipment, and sub‐assemblies.
Areias has experience with safety standards, and provide electrical and mechanical design of power and control panels.
Our Bill of Materials management allows for delivery of fully built and tested panels and assemblies.
UL508a | Standard for Safety of Industrial Control Panel |
NFPA79 | Electrical Standard for Industrial Machinery |
CE | EU CE Marking |
IEC 60204 | Safety of Machinery – Electrical Equipment of Machines |
IEC 61010 | Safety Requirement for Electrical Equipment for Measurement, Control, and Laboratory Use |
Samsung | Common Specification – Electrical |
Semi F47 | Voltage Sag and Immunity Standards |
Semi S2 | Environmental, Health, and Safety Guideline for Semiconductor Manufacturing Equipment |
Areias has experience with various electrical standards and listed for designing and building to UL508a.
Our engineers are familiar with designing and building electrical and control panels that are serviceable.
Areias has experience with selecting electrical components that meet UL508a and other requirements.
Our engineers are familiar with the individual specification requirement for components such as the following examples:
– Branch and supplementary protection
– Low voltage limited energy control circuit
– Emergency stop
– Ring lug usage
Actuators | Fans | Relays |
Circuit Breakers | Fuses | Resistors |
Connectors | Labels | Sensors |
Controllers | Line Filters | Solid State Relays |
Displays | Motors | Switches |
EMI Filters | PLCs | Terminal Blocks |
Enclosures | Power Supplies | Transformers |
Areias has experience arranging components to meet UL508a and other requirements.
Our engineers are familiar with properly arranging components to meet requirements and manufacturer’s specification such the following examples:
– Protection from high voltage
– Operator accessibility
– Finger safety
– Spacing for air flow
– AC to DC separation
Areias has experience with designing electrical schematics to meet UL508a and other requirements.
Our engineers are familiar with properly laying out schematic to facilitate the user’s quick understanding of operation and location with consideration to the following examples:
– Component labeling
– Component operation
– Component rating
– Wire identification
Item | Component | Description | Manufacturer | MFG Part # | Qty | UOM |
0 | 02-22231-000 | ASSY,TRADESHOW BOX,STEVEN RITTAL,UL5084,AREIAS | 1 | EA | ||
0 | 09-22269-000 | SCH,TRADESHOW,STEVEN ENGINEERING,AREIAS SYS | 1 | EA | ||
1 | 61-22255-000 | SW,DISCONNECT,3P,16A,SCHNEIDER | SCHNEIDER ELECT | VL53P016R1 | 1 | EA |
2 | 61-22255-001 | SW,ACCESSORY,HANDLE,SCHNEIDER | SCHNEIDER ELECT | VLSH2HSRD | 1 | EA |
3 | 61-22255-002 | SW,ACCESSORY,SHAFT,SCHNEIDER | SCHNEIDER ELECT | VLSSSOOS | 1 | EA |
6 | 62-13179-100 | PS,24VDC,100W,4A,85-264VAC IN CLASS 2 PHOENIX UNO SERIES | PHOENIX | 2902993 | 1 | EA |
8 | 60-22273-000 | C8,1-P,6A,D-CURVE,UL489,SCHNEIDER | SCHNEIDER | M9F43106 | 1 | EA |
11 | 61-22268-000 | SENS,LASER DIFFUSE, CLASS 2 LASER, BANNER | BANNER ENGINEER | LTF12IC2LD | 1 | EA |
12 | 69-22711-004 | LED,LIGHT TOWER,24VDC,PROGRAMMABLE,4 SEG,BANNER | BANNER | DK-TLSOPRO-EDITOR | 1 | EA |
13 | 61-11160-RED | SW,PUSHBUTTON OPERATOR,EMO,40MM,TURN RESET,HW SERIES,IDEC | IDEC | HW18-V4R | 1 | EA |
14 | 61-11160-000 | SW,EMOSHROUD,40MM,HWSERIES,IDEC | IDEC | HW9Z-KG1 | 1 | EA |
15 | 85-22276-000 | FIT,SEALING FRAME,2X3 CONFIG,SMALL,PHOENIX | PHOENIX | 801660 | 1 | EA |
16 | 85-22276-CON | FIT,INSERT-CABLE SLV,SMALL,2-10MM,SEALING FRAME, PHOENIX | PHOENIX | 801718 | 2 | EA |
17 | 85-22276-PLG | FIT,INSERT-PLUG,SMALL,SEALING FRAME,PHOENIX | PHOENIX | 801670 | 4 | EA |
19 | 24-20578-000 | DIN RAIL,3SMMX7.5MM XIM,GALVANIZED,PHOENIX | PHOENIX | 807012 | 3 | FT |
Areias has experience with developing Bill of Materials to meet UL508a and other requirements.
Our engineers are familiar with properly generating a bill of materials to facilitate the procurement of components with consideration to the following examples:
– Material Requirement Planning software (MRP)
– Manufacturer information
– Availability
– Supply chain concerns
Areias has experience with generating manufacturing drawings to meet UL508a and other requirements.
Our engineers are familiar with properly generating a manufacturing drawing to facilitate assembly of components with consideration to the following examples:
– Component location
– Proper alignment
– Din rail placement
– Component identification
Areias has experience with building systems to meet UL508a and other requirements.
Our engineers are familiar with best know practice for building control panels with consideration to the following examples:
– Copy exact requirements
– Build to customer documentation
– Component and wire labeling
– Wire termination
– 100% final Quality Control
Areias has experience with various electrical standards and listed for designing and building to UL508a.
Our engineers are familiar with designing and building electrical and control panels that are safe and serviceable with operator safety being the primary concern.
UL508a | Standard for Safety of Industrial Control Panel |
NFPA79 | Electrical Standard for Industrial Machinery |
CE | EU CE Marking |
IEC 60204 | Safety of Machinery – Electrical Equipment of Machines |
IEC 61010 | Safety Requirement for Electrical Equipment for Measurement, Control, and Laboratory Use |
Samsung | Common Specification - Electrical |
Semi F47 | Voltage Sag and Immunity Standards |
Semi S2 | Environmental, Health, and Safety Guideline for Semiconductor Manufacturing Equipment |
Areias has experience with selecting electrical components that
meet UL508a and other requirements.
Our engineers are familiar with the individual specification requirement for components such as the following examples:
- Branch and supplementary protection
- Low voltage limited energy control circuit
- Emergency stop
- Ring lug usage
Actuators | Fans | Relays |
Circuit Breakers | Fuses | Resistors |
Connectors | Labels | Sensors |
Controllers | Line Filters | Solid State Relays |
Displays | Motors | Switches |
EMI Filters | PLCs | Terminal Blocks |
Enclosures | Power Supplies | Transformers |
Areias has experience arranging components to meet UL508a and other requirements.
Our engineers are familiar with properly arranging components to meet requirements and manufacturer’s specification such the following examples:
- Protection from high voltage
- Operator accessibility
- Finger safety
- Spacing for air flow
- AC to DC separation
Areias has experience with designing electrical schematics to meet UL508a and other requirements.
Our engineers are familiar with properly laying out schematic to facilitate the user’s quick understanding of operation and location with consideration to the following examples:
- Component labeling
- Component operation
- Component rating
- Wire identification
Areias has experience with developing Bill of Materials to meet UL508a and other requirements.
Our engineers are familiar with properly generating a bill of materials to facilitate the procurement of components with consideration to the following examples:
- Material Requirement Planning software (MRP)
- Manufacturer information
- Availability
- Supply chain concerns
Areias has experience with generating manufacturing drawings to meet UL508a and other requirements.
Our engineers are familiar with properly generating a manufacturing drawing to facilitate assembly of components with consideration to the following examples:
- Component location
- Proper alignment
- Din rail placement
- Component identification
Areias has experience with building systems to meet UL508a and other requirements.
Our engineers are familiar with best know practice for building control panels with consideration to the following examples:
- Copy exact requirements
- Build to customer documentation
- Component and wire labeling
- Wire termination
- 100% final Quality Control